(a)The following information shall be included in each roof control plan:
(1)The name and address of the company.
(2)The name, address, mine identification number and location of the mine.
(3)The name and title of the company official responsible for the plan.
(4)A typical columnar section of the mine strata which shall---
(i)Show the name and the thickness of the coalbed to be mined and any persistent partings;
(ii)Identify the type and show the thickness of each stratum up to and including the main roof above the coalbed and for distance of at least 10 feet below the coalbed; and
(iii)Indicate the maximum cover over the area to be mined.
(5)A description and drawings of the sequence of installation and spacing of supports for each method of mining used.
(6)When an ATRS system is used, the maximum distance that an ATRS system is to be set beyond the last row of permanent support.
(7)When tunnel liners or arches are to be used for roof support, specifications and installation procedures for the liners or arches.
(8)Drawings indicating the planned width of openings, size of pillars, method of pillar recovery, and the sequence of mining pillars.
(9)A list of all support materials required to be used in the roof, face and rib control system, including, if roof bolts are to be installed---
(i)The length, diameter, grade and type of anchorage unit to be used;
(ii)The drill hole size to be used; and
(iii)The installed torque or tension range for tensioned roof bolts.
(10)When mechanically anchored tensioned roof bolts are used, the intervals at which test holes will be drilled.
(11)A description of the method of protecting persons---
(i)From falling material at drift openings; and
(ii)When mining approaches within 150 feet of an outcrop.
(12)A description of the roof and rib support necessary for the refuge alternatives.
(b)Each drawing submitted with a roof control plan shall contain a legend explaining all symbols used and shall specify the scale of the drawing which shall not be less than 5 feet to the inch or more than 20 feet to the inch.
(c)All roof control plan information, including drawings, shall be submitted on 8 1/2 by 11 inch paper, or paper folded to this size. \[53 FR 2375, Jan. 27, 1988, as amended at 60 FR 33723, June 29, 1995; 73 FR 80697, Dec. 31, 2008\]
Connections7 cite this
Citation graph
cites case law
§ 75.221
Roof control plan information.
Fed. Reg.×7
Cites 0Cited by 7 across 1 source
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.